Designs & Manufacture of Rack Cabinet

IP-54 RACK CABINET - 19 InchIP-54 RACK CABINET - 21 InchRACK CABINET - 19 InchWALL MOUNT CABINET - 19 Inch

19inchimage

19 inch

19inchimage

21inch

rackcabonetimage

19inchrc

 wallmountimage

wallmount

Features                  Construction & Finish                Standard Conformance               Custom Requirements                Options

Features

  • Doors are hung on multiple hinges and secured in the closed position by a multipoint locking system activated by semi-flush fitting, “lift & swing” key lockable handle. The entire hinge and locking system is located outside the gasketed cabinet front, i.e. these locks rods do not encroach into the working area of the cabinet. Further, as this complete hinge/lock system is symmetrical, rehanging a left hand door to right hand can be accomplished “on site” with the aid just a screwdriver. The 6RU and 12RU cabinets have a single point lock and provision to reverse hand the door.
  • Rack Mounting Angles are finished in colour powder cost. Four are supplied as standard and are fully adjustable within the cabinet confirming to IEC 6097 practice.
  • Cable access to the cabinet is provided at the base where there are cable entries fitted with protective gland plates. Alternative requirements should be discussed at the time of ordering.
  • Eye Bolt provision for mounting eye bolts is made on all cabinets. However, the eye bolts must be ordered if required. Load capacity of 600kg is considered safe, but Spreader Bars must be used to meet this rating.

Construction and Finished

The cabinet components are fabricated from phosphate steel and are powder coated prior

to assembly to ensure accurate distortion free reproduction.

These cabinets are constructed using modern assembly techniques, welding has been almost completely eliminated.

Standard Conformance

All standard 19” cabinets generally conform to IEC 60297 19” standard.

The industrial Cabinet can be manufactured to conform to IP55 dust and moisture specifications, subject to customer requirements. IP66 can be supplied at extra cost.

Custom Requirements

Special punching requirement, the inclusion of special brackets etc., can be readily undertaken.

These are best done at the outset of a project rather than attempting to add later.

Whilst we consider our range extensive, sometimes a special size is required.

These will be willingly undertaken but may require lead time.

Please contact our Sales Department for further assistance.

Options

  • A full height glass panel of a glass port to suit your specific requirements can be positioned in the door.
  • Gear trays can be fitted inside the rear of the cabinet, either full height or partial, finished either white or international orange baked enamel. They are fabricated in 3mm steel.
  • The plinth is 90mm high and incorporates levelling feet, bolt down brackets to secure to the floor and finished in colour powder coat.
  • A weather Hood for cabinets used outdoors is available. This hood provides additional protection from the elements.
  • Venting can be provided through the additional of louring the cabinets, will remain drip proof but it will no longer meet the IP55 dust and moisture specification. There is also a range of fan units and air conditioners that can be incorporated into the cabinet.
  • The fan units to suit these cabinets are fixed inside the cabinet behind the louvers and exhaust air out of the cabinet. A group of air intake louvers are also needed. These need to be of equal size to the exhaust louvers to work efficiently and can be fitted with removable dust filters/Insect screen.
Power Distribution          Plinth & Base           Air Management                Shelves                   Panels                19” 3U AC DB         Miscellaneous         

Power Distribution

powerdistimage

Horizontal Power Distribution Panel

Vertical Power Distribution Panel

  • The panel is supplied fully wired with outlets, lead and plug.
  • The panel is using Singapore type of power distribution sockets.
  • Singapore 13A,240V

powerdistimage2

Plinth & Base

pb1

Base

  • Include optional plate covered cable entry at the front and/or back.
  • Include removable ventilation grille to permit air entry to the cabinet when it is mounted on a solid floor
  • Increase overall height

p2

Castor Wheel

  • Max load 200 KG
  • Brakes can be supplied

p3

Levelling Feet / Foot Adjuster

  • Max load 300 KG
  • Can be fitted to all cabinet
  • With Metal or Rubber can be supplied

Air Management

am1

am2

AC Fan

  • Aluminium cast frame
  • Impedance Protection
  • Rotation clockwise view from label side

Removable Filter

  • Removable Filters can be used in conjunction with louvres to assist with the prevention of dust entering to the Rack Cabinet
  • Prevent insect to entering the Rack Cabinet
  • Easily to remove and wash
  • If the Filter spoil, it is easy to replaced

Shelves

shelves1

shelves2Fixed Equipment Rails

  • All equipment rails can carry loads more than 50kg equipment
  • Support heavy equipment that is either being installed or removed

Panels

panels

19” 3U AC DB For Rack Mount

3U AC DB

Miscellaneous

 

krone1